««ª½¿U¿N©Ê¸ÕÅç¾÷
FAR²Ä25³¡¤ÀApp F²ÄI³¡¤À¡AAITM 2.0002¡ABSS 7230¡AFTM 5903¡AASTM F 1506
««ª½¥i¿U«Ç¥Î©ó§÷®Æªº¦UºØ¨¾¤õ´ú¸Õ¡A¥]¬A²Ä25³¡¤Àªþ¿ýF²Ä1¡]b¡^¡]4¡^³¡¤À– 12¬í©M60¬í´ú¸Õ¡AªÅ¤¤«È¨®AITM 2.0002A¡F AITM 2.0002B¡AªiµBSS 7230 F1©MF2¡A¯Ã¬ù/·s¿A¦è¦{¤º¹¢©M¥¬®Æ§÷®Æ´ä¤fºÞ²z§½¥H¤ÎCPAI 84±bÁO¤º¾À©M³»³¡¡C
³W®æ»P¥\¯à
• ¥ÑÀu½è©Ôµ·¤£ù׿û»s¦¨
• ³z¹L¼·½L¶}Ãö¹ê²{¥þ¦Û°Ê¤õµK¼²À»
• ÂI¤õ®É¶¡±q0 – 60¬í¥i½Õ
• ¥i¿ï¾Ü©M¦Û°Ê±±¨î¤õµK¬I¥[®É¶¡
• ¦Û¥Ñ¹B¦æªº©TºA¼Æ¦rp®É¾¹°O¿ýÁ`¿U¿N®É¶¡¡AµM«á¥Î©ópºâ¿U¿N²v
• ±Ò¥Î“¤õµK«á”“ºw¸¨”®É¶¡°O¿ý
• ¿U¿N¾¹°ª«×©M¨¤«×¥i½Õ
• ¥]¬A¼Ë«~§¨¨ã
§Þ³N¼Æ¾Ú©Mn¨D
¹q®ð¡G230 vAC 50 Hz volts/ 115 vAC 60 Hz
Àô¹Ò·Å«×¡G¤u§@·Å«×10°C¦Ü35°C
¨Ñ®ð¡G
¼ÐºÙȬ°0.2 Bar¡]2.5 psi¡^ªº³Ì§C¯Â«×¬°99¢Hªº°Ó·~¯Å¥ÒÖJ
¤Ø¤o¡G430 mm¡]¼e¡^x 800 mm x¡]°ª¡^x 330 mm¡]²`¡^
Vertical Flammability Chamber
FAR Part 25 App F Part I, AITM 2.0002, BSS 7230, FTM 5903, ASTM F 1506
The Vertical Flammability Chamber is used in various areas of fire testing of materials, including Part 25 Appendix F Part 1(b)(4) – 12 second & 60 seconds Tests, Airbus AITM 2.0002A; AITM 2.0002B, Boeing BSS 7230 F1 and F2, NY/NJ Port Authority for Upholstery and Drapery Materials and CPAI 84 Tent Walls and Tops.
Specification & Features
•Fabricated from high quality brushed stainless steel
•Fully automatic flame impingement accomplished by a switch of the dial
•Adjustable Ignition time from 0 – 60 seconds
•Selectable and automated control of flame application time
•Free running solid state digital timer to record total burning time, which is then used to calculate burn rate
•Enables “after flame” “dripping” timings to be recorded
•Burner height and angle adjustable
•Specimen holder included
Options:
• Thermocouple c/w digital meter to measure flame temperature
• Spare Specimen Holder Set
• Set of Hooked Weights
Technical Data & Requirements
Electrical: 230 vAC 50 Hz volts / 115 vAC 60 Hz
Ambient Temperature: Operating 10°C to 35°C
Gas Supply:
Commercial grade methane of minimum purity of 99% at a pressure of 0.2 Bar (2.5 psi) nominal
Dimensions: 430 mm (W) x 800 mm x (H) x 330 mm (D)